某某清洁服务有限公司

SEARCH:
Content
EG-1200Y Infusion Pump with Drug Library
EG-1200Y Infusion Pump with Drug Library
1. Can be used for all standards of sterile burette type infusion set for single use (Correspond ISO 8536-4:2007 standard).
2. Automatic Calibration for IV sets.
3. Five working modes: Rate mode, Time mode, Volumetric mode, Dose mode and Drug library mode.
4. Built in rechargeable battery (Lithium-ion polymer battery).
5. Spec of the fuse: F1AL/250V, two (inside).

Features


1. Can be used for all standards of sterile burette type infusion set for single use (Correspond ISO 8536-4:2007 standard). 
2. Automatic Calibration for IV sets. 
3. Five working modes: Rate mode, Time mode, Volumetric mode, Dose mode and Drug library mode. 
4. Built in rechargeable battery (Lithium-ion polymer battery). 
5. Spec of the fuse: F1AL/250V, two (inside). 
6. 8 hours internal battery backup. 
7. Alarm functions: occlusion, empty bottle, low battery, rate error, end of infusion, door open, air in line etc 
8. Three levels of the occlusion limited pressure: high, middle and low.  
9. Three levels of alarm sound: high, middle and low.  
10. The infusion pump goes into KVO mode automatically as infusion is completed. 
11. Purge and Bolus functions 
12. Anti-bolus function 
13. History records being demanded directly. And with RS232 ports as well, in order to connect other 

equipments.  
14. Waterproof class: IPX4 


Technical Specification


1. Flow range : 1.0~99.9ml/h, 0.1ml/h increment                                          
                       100~1200ml/h, 1ml/h increment 
                   or 1~400drops/min, 1 drop/min increment. 
2. Flow precision : ± 5%  
3. Target volume (TAR VOL): 0.1~99.9ml, 0.1 ml increment; 100~9999 ml, 1ml increment. 
4. Infusion time (TIME): 1min~6000min, increment 1min. 
5. Adjustable range of infusion precision:-50%~+50%, increment:1% (for volumetric mode).  
6. Infused Volume range: 0.1~99.9ml increment 0.1ml; 100~9999ml, 1ml increment. 
7. Adjustable ranges of Sol. Vol, Drug Mass, Dose: 
                           Sol. Vol (solution Volume): 1~9999 ml, increment: 1ml 
8. Drug Mass: 0.1~999.9, increment: 0.1, Unit: g, mg, U, IU; 
9. Dose: 0.001~9.999, increment: 0.001; 10.00~99.99, increment: 0.01; 
10. 100.0~999.9, increment 0.1;1000~9999, increment 1; 
11. Dose units: ng/kg/min; ug/kg/min; mg/kg/min; g/kg/min; Ug/kg/h; mg/kg/h; g/kg/h; 
                    ug/min; mg/min; g/min; ug/h; mg/h; g/h; U/min; U/h; IU/h; U/kg/h; mg/kg; ml/min; ml/h; 
12. Body Weight range: 0.1~300.0kg, increment: 0.1kg 
13. Purge: 600 ml/h. 
14. 
Bolus: Adjustable from 1~1200ml/h, in steps of 0.1ml/h (if flow rate < 100ml/h) and 1ml/h 

(if flow rate > 100ml/h), Target Volume:1~500 ml, in steps of 1ml 
15. KVO rate: if the flow rate ≤10 ml/h, KVO is 1ml/h. 
  Otherwise KVO is 3ml/h. 
16. Power supply: AC100~240V, 50/60Hz, Internal Lithium-ion polymer battery: DC 11.1V,  ≥1600mAh. 

     The battery backup is approx. 8 hours (when using a fully charged battery and running at 20drops/min 

      with any standard IV Set). 
17. Power consumption:≤25VA 
18. Class: I 
19. Type    : CF  
20. Size: 125mm(W)×230mm(H)×125mm(D) 
21. Net weight: approx. 2kg 
22. Operating condition:  
  Ambient temperature: 5~40 degree C,  
  Relative humidity: 20~90% 
23. Storage condition: 
   Ambient temperature: -10~55 degree C 
   Relative humidity   : 10~90%.

脚注栏目
自定内容
2006-2015 Everglorious Medical . All rights reserved