Bi-level Positive Airway Pressure (BiPAP)
4 sub-models (BPAP-25, 25A, 25T, 30T)
ESmart BPAP
Bi-level Positive Airway Pressure (BiPAP)
With RESlex (Expiration Pressure Release)
RESmart BPAP Series offers the ultimate in sleep therapy comfort. It combines auto adjusting pressure delivery with the breath-by-breath pressure relief of RESlexTM for most natural sleep therapy. It also can provide non-invasive ventilation for patients with respiratory insufficiency in the hospital or home.
Professional precision
- Innovative tracking technology ensures accurate and comfortable therapy.
- Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort.
- RESlex performs better exhalation and compliance.
- Inspiration trigger for auto start-up.
- Automatic stop after put off mask.
- Alarm when accidental power-off.
- In time alert function when mask/tubing off-line.
- Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.
Ergonomic and powerful design
- Integrated and knock-down designed InH2TM heated humidifier.
- DC 24V powered and infrared controlled humidifier make user safe and comfortable.
- Smart Heater automatic restarts after short term break.
- Patented anti-countercurrent water tank
- Unique Delay-off feature protects RESmart BPAP from humidity hazard.
- Powerful embedded memory stores last night’s full raw data, 365 nights’ user Blog and more than 30 years’ therapy record.
- User Blog direct output via portable thermal printer.
Technical Specifications:
Device Size
Dimensions: 220 × 194 × 112 mm
313 × 194 × 112 mm (with InH2TM heated humidifier)
Weight: < 2.2 kg
< 3 kg (with InH2TM heated humidifier)
Environmental
|
Operating |
Transport and Storage |
Temperature |
5 to 30°C |
-20 to 55°C |
Relative Humidity |
≤ 80% Non-condensing |
≤ 93% Non-condensing |
Atmospheric Pressure |
860 to 1060 hPa |
500 to 1060 hPa |
Standards Compliance
IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment
IEC 60601-1-2 Electromagnetic Compatibility
ISO 17510 Sleep Apnoea Breathing Therapy
ISO 8185 General Requirements for Humidification Systems
Electrical
AC Power Consumption: 100 - 240V AC, 50/60Hz, Max 95VA
Type of Protection Against Electric Shock: Class II Equipment
Degree of Protection Against Electric Shock: Type BF Applied Part
Degree of Protection Against Ingress of Water: Drip Proof, IPX1
Mode of Operation: Continuous
Model Comparison
Product Model |
Pressure |
Function |
Auto Pressure |
RESmart® BPAP 25 |
4-25 cmH2O |
S, CPAP |
No |
RESmart® BPAP 25A |
4-25 cmH2O |
S, CPAP |
available |
RESmart® BPAP 25T |
4-25 cmH2O |
S, CPAP, T, S/T |
No |
RESmart® BPAP 30T |
4-30 cmH2O |
S, CPAP, T, S/T |
No |
Pressure
IPAP 4 to 30 cmH2O* ±1 cmH2O**
EPAP 4 to 25 cmH2O* ±1 cmH2O**
CPAP 4 to 20 cmH2O ±1 cmH2O**
Respiratory Rate 3 to 40 BPM, Greater of ±1 BPM or ±10% of the setting
(When measured over a 4 minutes period)
E/I Rate 1-4
Max. Inspiration Time 3.0 seconds
Ramp Duration 0 to 60 minutes ±10% of the setting
Rise Time 0 to 3*** ±25%****
* Limited to 20 cmH2O when using the Auto feature in S mode.
** Dynamic pressure accuracy is ±1 cmH2O measured at the patient end of the circuit with a Vio Nasal Mask and varying flow conditions.
Static pressure accuracy is ±0.5 cmH2O measured at the patient end of the circuit with a Vio Nasal Mask and no patient flow.
*** The range of values corresponds to tenths of seconds (e.g., a setting of 4 indicates a Rise Time of 0.4 seconds).